Properties
- Powerful Peltier cooler with four long-life Peltier elements
- Precise output dew point even with heavy load changes
- Corrosion-resistant PVDF heat exchanger
- optinoal High-performance stainless steel heat exchanger
- 1 – 2 replaceable jet heat exchangers
- Very compact design
Wall mounting possible in 2 positions (back or right-side panel)
- Digital display for temperature & alarms
- Available with and without condensate pumps
Potential-free contacts for operational monitoring
Technical Data + Options
Application
The compact sample gas conditioning systems of the MAK 20 Peltier series are used for continuous extractive gas analysis. They are primarily used for precise, constant lowering of the sample gas dew point and thus for drying the humid sample gas flow. In this way, water vapour cross-sensitivities and volumetric errors are minimised and damage to the sensitive analyser is avoided.
Technology
The precise temperature control of the Peltier control in conjunction with the corrosion-resistant jet heat exchangers achieves low, extremely constant dew points. Load fluctuations and high thermal loads are also reliably equalized. The hydrophobic surface and the very short dwell time of the gas in the heat exchanger ensure the lowest possible gas solubility rates.
Functions
The electrical control of the MAK 20 Peltier monitors the cooling temperature and adjusts the cooling capacity of the individual Peltier elements to the current demand. The power-controlled fans dissipate the waste heat with the lowest possible noise level. The potential-free alarm contact enables remote monitoring of the device.
You may also be interested in
Exact linear flow rate adjustment with precise fine adjustment valve with high chemical resistance and optional light barrier sensor
Compressor Cooler for Process Measurement (outlet dew point optimized), 1-2 Gas Path, Stainless Steel Heat Exchanger , flow rates up to 500 l/h, Operating pressure up to 100 bar, Additional Temperature Display following SIL
Compressor Cooler for Process Measurement (outlet dew point optimized), 1-4 Gas Path, Heat Exchanger in various Materials, flow rates up to 500 l/h for ATEX EX II 2G Ex px de [ai] IIC T4 Gb
High Performance Compressor Cooler (outlet dew point optimized) with 1-4 Gas Path, Heat Exchanger in various Materials and flow rates up to 500 l/h
High Performance Compressor Cooler (outlet dew point optimized) with 1-4 Gas Path, Heat Exchanger in various Materials and flow rates up to 500 l/h
Compressor Cooler for Process Measurement (outlet dew point optimized), 1-2 Gas Path, Heat Exchanger in various Materials, flow rates up to 350 l/h for Atex-zone 2 (II 3G Ex nA nC T4 Gc)
High Performance Compressor Cooler (outlet dew point optimized) with 1-2 Gas Path, Heat Exchanger in various Materials and flow rates up to 350 l/h
High Performance Compressor Cooler (outlet dew point optimized) with 1-2 Gas Path, Heat Exchanger in various Materials and flow rates up to 250 l/h
Mobile Conditioning System for temporary CEMS, Thermoelectric Cooler Flow Rate up to 250 l/h, integrated Gas Sample Pump and Temoerature controller for PSG Plus Flex Plane integrated in a robust Peli Case
Compressor Cooler for CEMS (lowest wash out ratio) with JET Stream 1-4 Gas Path, Flow Rate up to 150 l/h and update options to full conditioing system
Compressor Cooler for CEMS (wash out optimized) with 1-4 Gas Path, Flow Rate up to 150 l/h and update options to full conditioing system, for mobile applications
Thermo Electric Cooler for CEMS (wash out optimized) with 1-2 Gas Path, Flow Rate up to 150 l/h and update options to full conditioing system
Compressor Cooler for CEMS (wash out optimized) with 1-4 Gas Path, Flow Rate up to 150 l/h and update options to full conditioing system
Compressor Cooler for CEMS applications, 1-2 Gas Path, PVDF Jetstream Heat Exchanger , flow rates up to 250 l/h
Condensate Separation for Pre-cooling to ambient temperature with high water vapour and ambient temperatures
Self-suctioning Peristaltic Pump SR 25 with Synchronous motor and high chemical resistance
Electronic Control for alerting liquid sensor and Potential-free switch-contact for liquid sensor alerting
Corrosion resistant PTFE diaphragm sample gas pump (Integration into the MAK product line possible)
Depth Filter for the protection of the Analyzer against fine dust in PTFE and Glass Fibber versions
Safe detection of condensate as protection for the Analyzer with long lasting platinum electrodes