Properties
Separation of condensate
Pre-cooling to ambient temperature for water vapor inlet dew points>65°C
Improved performance of sample gas cooler
Suitable for high temperatures
Condensate removal with peristaltic pump SR25
PVDF-hose fittings and mounting bracket
Corrosion resistant made of glass
Low wash out ratio
Technical Data and Options
Application
The pre-separator PS is designed specifically for gas analysis technology to relief sample gas coolers at high inlet temperatures up to 160°C and high water vapor inlet dew points above 65°C.
Technology
The pre-separator PS is made of corrosion resistant glass and equipped with PVDF hose fittings and a wall mounting bracket. It is designed so that the wash out ratio of water soluble gas components is minimized and a safe condensate separation for flow rates up to 500Nl/hr is guaranteed. For condensate removal the condensate pump SR25 is used.
Functions
The performance of the sample gas cooler is affected favorably by the pre-separator PS. The sample gas is pre-cooled in the pre-separator by ambient air. Reaching the dew point, water vapor condenses along the dew point line as a result of cooling. Condensate is separated from the sample gas, is collected in the separator and then continuously drained by the connected condensate pump SR25.
You may also be interested in
Exact linear flow rate adjustment with precise fine adjustment valve with high chemical resistance and optional light barrier sensor
Compressor Cooler for Process Measurement (outlet dew point optimized), 1-2 Gas Path, Stainless Steel Heat Exchanger , flow rates up to 500 l/h, Operating pressure up to 100 bar, Additional Temperature Display following SIL
Compressor Cooler for Process Measurement (outlet dew point optimized), 1-4 Gas Path, Heat Exchanger in various Materials, flow rates up to 500 l/h for ATEX EX II 2G Ex px de [ai] IIC T4 Gb
High Performance Compressor Cooler (outlet dew point optimized) with 1-4 Gas Path, Heat Exchanger in various Materials and flow rates up to 500 l/h
High Performance Compressor Cooler (outlet dew point optimized) with 1-4 Gas Path, Heat Exchanger in various Materials and flow rates up to 500 l/h
Compressor Cooler for Process Measurement (outlet dew point optimized), 1-2 Gas Path, Heat Exchanger in various Materials, flow rates up to 350 l/h for Atex-zone 2 (II 3G Ex nA nC T4 Gc)
High Performance Compressor Cooler (outlet dew point optimized) with 1-2 Gas Path, Heat Exchanger in various Materials and flow rates up to 350 l/h
High Performance Compressor Cooler (outlet dew point optimized) with 1-2 Gas Path, Heat Exchanger in various Materials and flow rates up to 250 l/h
Mobile Conditioning System for temporary CEMS, Thermoelectric Cooler Flow Rate up to 250 l/h, integrated Gas Sample Pump and Temoerature controller for PSG Plus Flex Plane integrated in a robust Peli Case
Thermoelectric Cooler for CEMS applications, 1-2 Gas Path, PVDF or SS Jetstream Heat Exchanger , flow rates up to 300 l/h
Compressor Cooler for CEMS (lowest wash out ratio) with JET Stream 1-4 Gas Path, Flow Rate up to 150 l/h and update options to full conditioing system
Compressor Cooler for CEMS (wash out optimized) with 1-4 Gas Path, Flow Rate up to 150 l/h and update options to full conditioing system, for mobile applications
Thermo Electric Cooler for CEMS (wash out optimized) with 1-2 Gas Path, Flow Rate up to 150 l/h and update options to full conditioing system
Compressor Cooler for CEMS (wash out optimized) with 1-4 Gas Path, Flow Rate up to 150 l/h and update options to full conditioing system
Compressor Cooler for CEMS applications, 1-2 Gas Path, PVDF Jetstream Heat Exchanger , flow rates up to 250 l/h
Self-suctioning Peristaltic Pump SR 25 with Synchronous motor and high chemical resistance
Electronic Control for alerting liquid sensor and Potential-free switch-contact for liquid sensor alerting
Corrosion resistant PTFE diaphragm sample gas pump (Integration into the MAK product line possible)
Depth Filter for the protection of the Analyzer against fine dust in PTFE and Glass Fibber versions
Safe detection of condensate as protection for the Analyzer with long lasting platinum electrodes