Properties
High performance thermoelectric cooler with two long lasting peltier-elements
Precise outlet dew point even at significant load variations
Corrosion resistant dual path PVDF heat exchanger
Corrosion resistant dual path PVDF heat exchanger
Very compact design
Extremely robust transport case
Integrated with the <
Same footprint as the MET-Nomad
Out-of-range temperature alarm
Integrated peristalitic pumps
Technical Data and Options
Application
The mobile sample gas coolers series MAK Mobileare used for extractive gas analysis and can be integrated with the MET Mobile Peltier to complete a mercury backup monitoring system. They serve primarily for exact constant lowering of the sample gas dew point and thus for drying of the humid sample gas flow. In this way water vapor cross sensitivities and volumetric errors are minimized and damages of the sensible analyzers are avoided. With optional HVAC system the MAK Mobile is suitable also for extreme conditions.
Technology
The precise temperature control of MAK Mobile with pulse width modulation in combination with the innovative corrosion resistant heat exchangers achieves low extremely constant dew points. Also load fluctuations and high thermal stress is compensated reliably
Functions
An electronic display unit for performance feedback controls dew point and cooling air temperature. Potential free alarm contacts allow remote monitoring of the device. Operating parameters are stored for diagnosis in a log. An operation hours counter controls the service intervals.
You may also be interested in
Exact linear flow rate adjustment with precise fine adjustment valve with high chemical resistance and optional light barrier sensor
Compressor Cooler for Process Measurement (outlet dew point optimized), 1-2 Gas Path, Stainless Steel Heat Exchanger , flow rates up to 500 l/h, Operating pressure up to 100 bar, Additional Temperature Display following SIL
Compressor Cooler for Process Measurement (outlet dew point optimized), 1-4 Gas Path, Heat Exchanger in various Materials, flow rates up to 500 l/h for ATEX EX II 2G Ex px de [ai] IIC T4 Gb
High Performance Compressor Cooler (outlet dew point optimized) with 1-4 Gas Path, Heat Exchanger in various Materials and flow rates up to 500 l/h
High Performance Compressor Cooler (outlet dew point optimized) with 1-4 Gas Path, Heat Exchanger in various Materials and flow rates up to 500 l/h
Compressor Cooler for Process Measurement (outlet dew point optimized), 1-2 Gas Path, Heat Exchanger in various Materials, flow rates up to 350 l/h for Atex-zone 2 (II 3G Ex nA nC T4 Gc)
High Performance Compressor Cooler (outlet dew point optimized) with 1-2 Gas Path, Heat Exchanger in various Materials and flow rates up to 350 l/h
High Performance Compressor Cooler (outlet dew point optimized) with 1-2 Gas Path, Heat Exchanger in various Materials and flow rates up to 250 l/h
Thermoelectric Cooler for CEMS applications, 1-2 Gas Path, PVDF or SS Jetstream Heat Exchanger , flow rates up to 300 l/h
Compressor Cooler for CEMS (lowest wash out ratio) with JET Stream 1-4 Gas Path, Flow Rate up to 150 l/h and update options to full conditioing system
Compressor Cooler for CEMS (wash out optimized) with 1-4 Gas Path, Flow Rate up to 150 l/h and update options to full conditioing system, for mobile applications
Thermo Electric Cooler for CEMS (wash out optimized) with 1-2 Gas Path, Flow Rate up to 150 l/h and update options to full conditioing system
Compressor Cooler for CEMS (wash out optimized) with 1-4 Gas Path, Flow Rate up to 150 l/h and update options to full conditioing system
Compressor Cooler for CEMS applications, 1-2 Gas Path, PVDF Jetstream Heat Exchanger , flow rates up to 250 l/h
Condensate Separation for Pre-cooling to ambient temperature with high water vapour and ambient temperatures
Self-suctioning Peristaltic Pump SR 25 with Synchronous motor and high chemical resistance
Electronic Control for alerting liquid sensor and Potential-free switch-contact for liquid sensor alerting
Corrosion resistant PTFE diaphragm sample gas pump (Integration into the MAK product line possible)
Depth Filter for the protection of the Analyzer against fine dust in PTFE and Glass Fibber versions
Safe detection of condensate as protection for the Analyzer with long lasting platinum electrodes